Soil & Waste Systems

Complete above-ground drainage for domestic and commercial applications. Choose from push-fit, solvent weld, or ring seal jointing—whatever suits your project and working preferences.

Three Jointing Systems UK Manufactured Kitemark Certified

Waste Pipe Systems

32mm, 40mm, and 50mm for basin, sink, bath, and shower drainage.

32mm

32mm Waste

Basin/Overflow

Push-fit & Solvent weld options
40mm

40mm Waste

Sink/Bath/Shower

Push-fit & Solvent weld options
50mm

50mm Waste

Commercial

Push-fit & Solvent weld options

Choose Your Jointing Method

Push-Fit

Fast installation with no setting time. Rubber seals grip the pipe while allowing removal for maintenance access.

  • ✓ Fastest installation
  • ✓ Maintenance access
  • ✓ No chemicals needed

Solvent Weld

Permanent welded joints using solvent cement. Creates the strongest joint for concealed and structural applications.

  • ✓ Strongest joint
  • ✓ Ideal for concealed work
  • ✓ Traditional method

Ring Seal

Large rubber seals providing flexibility and reliable sealing. Suits larger diameters and external applications.

  • ✓ Thermal movement
  • ✓ External installations
  • ✓ 160mm systems

Air Admittance Valves

110mm Pushfit and Solvent Weld Air Admittance Valves for soil stack ventilation. An alternative to traditional vent pipes where roof penetration isn't practical.

  • Standard: BS EN 12380:2002 Class A1 compliant
  • Operating range: -20°C to +60°C
  • Options: PFAV110B (Black), PFAV110G (Grey), PFAV110W (White)
  • Jointing: Push-fit and solvent weld versions available
Download AAV Data Sheet

Certifications & Standards

  • BSI Kitemark: KM 593499 (BS EN 1329-1)
  • Standard: BS EN 1329-1 — Soil & waste PVC-U piping
  • Material: PVC-U to European standards
  • Colours: White (RAL 9010), Black (RAL 9005), Grey (RAL 7001)

POE Oil Warning — Important Safety Notice

Polyol Ester (POE) oil used in modern refrigeration compressors can cause Environmental Stress Cracking in PVC and ABS pipes. If soil and waste systems are located near refrigeration or air conditioning units, take care to prevent POE oil contact with pipework.

Download Full POE Oil Advisory (PDF)